Wally medical school freshman
Joined: 13 Dec 2004 Posts: 24 Location: Panhandle Gulf Coast |
Posted: Tue May 24, 2005 10:17 am Post subject: 7000 toner |
|
|
I have a 7000 in house with 450K. The toner light comes on about every 100 sq's. We remove toner and shake and reinstall.
Printer will run short time and shut down with toner light on.
Any help with this issue.
Mike |
|
|
|
|
|
|
|
|
|
|
CopyTek medical school senior
Joined: 13 Jan 2005 Posts: 33 Location: SW Florida |
Posted: Tue May 24, 2005 4:58 pm Post subject: |
|
|
Just a thought, the way I load toner on the kip6000\7000 is after shaking the toner (smoothing it) I shake it one last time all to the left then install. I know on a lot of machines you shake the toner in cartriges then level it before install, but I found if you encourage all the toner in cartridge to left then install it helps alot. Hope that's of some help _________________ This day will be my best day ever! |
|
|
|
|
|
|
|
|
|
|
KIPDOCTOR Site Admin
Joined: 31 Dec 1969 Posts: 1408 Location: Boston Area |
Posted: Tue May 24, 2005 5:45 pm Post subject: |
|
|
The toner sensor in this model and the 6000 is Mickey Mouse at best.
Obviously thought up after a bad night of drinking sake'.
It is simply a weight sensor and is very sensitive.
You can adjust the positioning of the sensor arrray or adjust the spring for the linkage.
PS this is a very common issue on the 6000 and 7000. _________________ What we have gained in technology, we have lost in humanity. |
|
|
|
|
|
|
|
|
|
|
Kipintern doctor
Joined: 04 Dec 2004 Posts: 378 Location: Infinity & Beyond Here on Earth Too! |
Posted: Thu May 26, 2005 9:41 pm Post subject: Fix |
|
|
All toner in cartridges should be on left prior to opening also You can adjust the triger to read at a different point this should help |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|