Home of the Kip Doctor!
REGISTER: In order to register for our forums please send an E mail to [email protected] stating what user name and password you would like. This is now required due to all the spambots that have been registering.
|
KeepItPrinting.com The "unofficial' and "unauthorized" KIP info site.
|
|
|
|
|
|
|
|
|
|
|
Martin medical school grad
Joined: 13 Dec 2004 Posts: 57 Location: Iowa City, IA |
Posted: Fri Mar 25, 2005 7:14 pm Post subject: Banding on halftones. . . |
|
|
I have been getting a lot of banding lately from one of our 8000's, only on halftone images. Line drawings come out fine.
It usually starts about 6 inches from the lead edge and continues to the end of the image.
Not really ghosting, just banding.
What do you guys think? |
|
|
|
|
|
|
|
|
|
|
KIPDOCTOR Site Admin
Joined: 31 Dec 1969 Posts: 1408 Location: Boston Area |
Posted: Fri Mar 25, 2005 9:09 pm Post subject: |
|
|
Sounds like possibly the dev unit is getting ready to be serviced/rebuilt/refreshed.
Gray scales are the first to show it.
Also could be grid plate. _________________ What we have gained in technology, we have lost in humanity. |
|
|
|
|
|
|
|
|
|
|
Martin medical school grad
Joined: 13 Dec 2004 Posts: 57 Location: Iowa City, IA |
Posted: Mon Mar 28, 2005 1:16 pm Post subject: |
|
|
The grid plate is brand new, so I guess dev unit it is.
That's the direction I was leaning, but I wanted some extra confirmation before I tore into it.
I guess my shirt will be dirty tonight. . .
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
You cannot post new topics in this forum You cannot reply to topics in this forum You cannot edit your posts in this forum You cannot delete your posts in this forum You cannot vote in polls in this forum
|
|
|
|