Wally medical school freshman
Joined: 13 Dec 2004 Posts: 24 Location: Panhandle Gulf Coast |
Posted: Fri Jan 14, 2005 4:30 pm Post subject: KIP 6000 |
|
|
I have a 6000 that keeps developing a line on extreme right of 36" wide print.
We can clean drum and line shows up after 2 days. Line is appox. 1/8" wide. Any thoughts on this?
Wally |
|
|
|
|
|
|
|
|
|
|
KIPDOCTOR Site Admin
Joined: 31 Dec 1969 Posts: 1408 Location: Boston Area |
Posted: Fri Jan 14, 2005 5:57 pm Post subject: |
|
|
(I moved this from the wrong forum)
Anyway, your problem is the wire cleaning pad gettinng hung up on the wrong side. Check it out and you will find that the rail it slides on is filled with burrs. File them off and you should be fine. _________________ What we have gained in technology, we have lost in humanity. |
|
|
|
|
|
|
|
|
|
|
Wally medical school freshman
Joined: 13 Dec 2004 Posts: 24 Location: Panhandle Gulf Coast |
Posted: Sat Jan 15, 2005 2:45 pm Post subject: KIP 6000 lines |
|
|
Thanks for the tip!!
I will check wire cleaning pad this wek. |
|
|
|
|
|
|
|
|
|
|
Kipintern doctor
Joined: 04 Dec 2004 Posts: 378 Location: Infinity & Beyond Here on Earth Too! |
Posted: Sat Jan 15, 2005 4:14 pm Post subject: lines |
|
|
Make sure your wires are tight use 100micron wire all around and if you arent certian you can get the wire snug use beads on the ends.
Provided you string them yourself. |
|
|
|
|
|
|
|
|
|
|
Kipintern doctor
Joined: 04 Dec 2004 Posts: 378 Location: Infinity & Beyond Here on Earth Too! |
Posted: Sat Jan 15, 2005 4:15 pm Post subject: Opps wrong answer to question |
|
|
Sorry I concur with the doctor. Probally the pad.
I answered the e51 question ! |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|