Haggis medical school grad
Joined: 29 Jun 2005 Posts: 62 Location: AZ |
Posted: Tue Aug 26, 2008 7:18 pm Post subject: tds 600 |
|
|
anyone seen a tds600 create a slight smearing of bold or heavy lines. Replaced all corona wires no change. i am thinking drum but..... thanks |
|
|
|
|
|
|
|
|
|
|
SHORTROUND resident
Joined: 23 Mar 2005 Posts: 155
|
Posted: Wed Aug 27, 2008 11:09 am Post subject: |
|
|
Does this happen on all sizes or just on larger sheets. If it is happing on 30x42 or larger I would check the cooling roller (exit roller). Check the absorber wires if toner is built up on the wires you will need to change the cooling roller. When the machine is running look into the fuser from the back and you will see the paper bulge causing the lines. I have found the rollers last about 1.3 million sq.feet.
hope this helps |
|
|
|
|
|
|
|
|
|
|
Haggis medical school grad
Joined: 29 Jun 2005 Posts: 62 Location: AZ |
Posted: Wed Sep 03, 2008 1:31 pm Post subject: |
|
|
i will check it out next time I am there. It is better but on heavy lines and text it still does it a little. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|