petergoyarts medical school freshman
Joined: 05 Oct 2007 Posts: 17
|
Posted: Wed Feb 27, 2008 7:01 pm Post subject: 7000 repeat image |
|
|
Gentlemen,
I have a 7000 with 1.3 million square on it. I cannot seem to solve the repeat image problem. I know that the image is staying on the drum and it is on the paper prior to going into the fuser. The repeat image is across the entire print. When i use the circumference sheet it points to pressure roller. The image repeats every 7 and 7/8ths and it will repeat three to four times maybe more. I have checked the cleaning roller connections as well. I have a new drum in the machine and have checked all the voltages. I am not sure that this is related but when you print a 36*60 TIF test print the smaller lighter lines don't show up at all on the left hand side. I checked the 36*60 and it is happening pre-fuser as well. Any one that could help me keep what hair I have left would be much appreciated. |
|
|
|
|
|
|
|
|
|
|
KIPDOCTOR Site Admin
Joined: 31 Dec 1969 Posts: 1408 Location: Boston Area |
Posted: Wed Feb 27, 2008 8:28 pm Post subject: |
|
|
Seen it a million (ok , maybe a few hundred) times. Text book developer issues. Time to refresh the dev unit. Don't waste your money on a rebuild kit, send the unit to us and will refresh it and send it back to you real quick. $849 is your cost. We have done hundreds of these.
Click the link at the bottom of the page with the hand holding all the money you will save.
Steve _________________ What we have gained in technology, we have lost in humanity. |
|
|
|
|
|
|
|
|
|
|
petergoyarts medical school freshman
Joined: 05 Oct 2007 Posts: 17
|
Posted: Fri Feb 29, 2008 7:29 pm Post subject: |
|
|
Steve,
Thank you for the quick response. I have had no fun dealing with this developer since we got it. As soon as i can talk my boss into it we will send it your way. Wondering if you recondition all makes of developers? Take Care,
Peter |
|
|
|
|
|
|
|
|
|
|
KIPDOCTOR Site Admin
Joined: 31 Dec 1969 Posts: 1408 Location: Boston Area |
Posted: Fri Feb 29, 2008 9:09 pm Post subject: |
|
|
We only refresh the KIP units. All models of KIP units now. _________________ What we have gained in technology, we have lost in humanity. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|