bogey0 medical school grad
Joined: 04 Aug 2009 Posts: 81
|
Posted: Tue Aug 17, 2010 8:37 pm Post subject: 4000ps alignment |
|
|
Customer uses this machine for cadd plots only. Normal D size print will show alignment issues with every pass of the carriage. It's only off by a mil, but looks like crap over the course of the print. Looking at the border left and right, you can see the steps right away. Printhead alignment does no good. Any ideas? |
|
|
|
|
|
|
|
|
|
|
Chazbo doctor
Joined: 05 Jul 2005 Posts: 377
|
Posted: Wed Aug 18, 2010 10:09 am Post subject: |
|
|
carriage belt worn, encoder strip damaged/dirty, scan axis calibration, media selection type. did you perform the "service image quality diagnostic print"? _________________ Ride To Live |
|
|
|
|
|
|
|
|
|
|
bogey0 medical school grad
Joined: 04 Aug 2009 Posts: 81
|
Posted: Thu Aug 19, 2010 4:56 pm Post subject: |
|
|
New belt, new encoder strip, all calibrations done without error, media correct, diagnostic print looks fine.
Apparently they had the autocad driver set to draft mode. Using default settings for line/text, the machine slows down enough that the prints are perfect. Thanks for the reply Chaz. |
|
|
|
|
|
|
|
|
|
|
Chazbo doctor
Joined: 05 Jul 2005 Posts: 377
|
Posted: Thu Aug 19, 2010 9:29 pm Post subject: |
|
|
WOW!...that's a new one. _________________ Ride To Live |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|